Belgium
Country/Region
Hitachi Medical Systems Europe

SCENARIA

Brilliance in modern volume CT

Product Picture for "SCENARIA"

The SCENARIA is Hitachi's new 64 multi-slice CT system which paves the way for the future. SCENARIA is a whole body scanner with a 0.35-second rotation speed which reduces dosage and speeds up workflow, while maintaining excellent diagnostic imagery.

The 750mm aperture maximises patients' comfort, reduces anxiety and stress, and enables effortless examinations.

  • Minimum scan time: 0.35 sec whole body scanning
  • Maximum field of view: 500mm
  • 2880 view/sec high-speed data acquisition
  • Gantry aperture of 75cm
  • Number of slices: 64
  • X-ray tube: 7.5 MHU
  • Generator: 72k
  • Dose reduction achieved by lateral table movement, bow-tie filter, Automatic Exposure Control (Intelli EC) and Interactive Processing (Intelli IP)
  • 16cm lateral table movement for dose reduction and increased patient comfort
  • Automatic patient positioning (head/body mode)
  • Breath demo light for patient preparation
  • Touch vision panel system, allowing scan guidance in 10 languages as well as paediatric assistance
  • Straight forward patient registration and easy system handling
  • Preventive examination supported by fatPointer or riskPointer
  • Integrated image viewing station
  • Coronary analysis and calcium scoring
  • Cruising Eye View (CEV-CPR), with virtual endoscopy
  • Perfusion stroke analysis
  • Predict scan contrast agent-triggering
  • Interventional procedure package Guide Shot
  • Hyper Q-net image viewing
  • FatPointer analysis software
  • RiskPointer analysis software
  • Real-time MPR
  • Complete 3D reconstruction package
  • Automatic bone removal
  • Virtual colonoscopy with Shape Analysis Filer
  • Lung analysis nodule detection
  • Cardiac scanning (ECG trigger, retrospective/prospective mode)
<b>High-speed whole body scanning</b><br />Whole body scanning (1,700mm) can be done in 10 sec .
High-speed whole body scanning
Whole body scanning (1,700mm) can be done in 10 sec .
<b>High-speed whole body scanning</b><br />0.35sec, BP 0.83, 5mm slice width, 500mA (175mAs), only 6.5 sec  from lung - pelvis with 0.35sec/rot
High-speed whole body scanning
0.35sec, BP 0.83, 5mm slice width, 500mA (175mAs), only 6.5 sec from lung - pelvis with 0.35sec/rot
<b>Cardiac 3D</b><br />The three-dimensional picture acquired together with electrocardiogram data. ECG triggering both retrospective and prospective mode possible.
Cardiac 3D
The three-dimensional picture acquired together with electrocardiogram data. ECG triggering both retrospective and prospective mode possible.
<b>Cardiac-MPR</b><br />MPRs performed at oblique planes to the body or the coronary arteries.
Cardiac-MPR
MPRs performed at oblique planes to the body or the coronary arteries.
<b>Lung-nodule</b><br />Lung area analysis software 3D display and automatic volume calculation for nodules.
Lung-nodule
Lung area analysis software 3D display and automatic volume calculation for nodules.
<b>Body-angio MIP</b><br />Body angiography with automatic bone and table removal - MIP reconstruction.<br />Case: Aortic dissection. Left common iliac artery occlusion.<br />Scanning: P0.83, 0.5s, 360mA, 100kV, weight 80kg, contrast 80cc
Body-angio MIP
Body angiography with automatic bone and table removal - MIP reconstruction.
Case: Aortic dissection. Left common iliac artery occlusion.
Scanning: P0.83, 0.5s, 360mA, 100kV, weight 80kg, contrast 80cc
<b>Body-angio VR</b><br />Body angiography with automatic  table removal - colored volume rendering reconstruction.<br />Case:  Aortic dissection. Left common iliac artery occlusion.<br />Scanning: P0.83, 0.5s, 360mA, 100kV, weight 80kg, contrast 80cc
Body-angio VR
Body angiography with automatic table removal - colored volume rendering reconstruction.
Case: Aortic dissection. Left common iliac artery occlusion.
Scanning: P0.83, 0.5s, 360mA, 100kV, weight 80kg, contrast 80cc
<b>Colored whole body angio lower part </b><br />Save split image 2 x (512 x 512) matrix possible to see high resolution 3D image without doing partial reconstruction.
Colored whole body angio lower part
Save split image 2 x (512 x 512) matrix possible to see high resolution 3D image without doing partial reconstruction.
<b>Colored whole body angio upper part</b><br />Save split image 2x(512 x 512) matrix possible to see high resolution 3D image without doing partial reconstruction.
Colored whole body angio upper part
Save split image 2x(512 x 512) matrix possible to see high resolution 3D image without doing partial reconstruction.
<b>Colon analysis software</b><br />CT Colonoscopy with automatic colon area extraction from abdominal CT image. Display switchable to 'cruising', '3 section' and  'panorama` mode.
Colon analysis software
CT Colonoscopy with automatic colon area extraction from abdominal CT image. Display switchable to 'cruising', '3 section' and 'panorama` mode.
<b>Colonoscopy shape analysis</b><br />Color and display to process possible. Shape analysis filter (colored polyp on panoramic image)
Colonoscopy shape analysis
Color and display to process possible. Shape analysis filter (colored polyp on panoramic image)
<b>High pitch scanning abdomen</b><br />0,5 sec/rotation, BP (BeamPitch) 1.08, 0.625mm slice width, 500mA (250mAs). High-pitch scanning  possible for routine examination. 475 mm abdomen scannable within 5.5 seconds.
High pitch scanning abdomen
0,5 sec/rotation, BP (BeamPitch) 1.08, 0.625mm slice width, 500mA (250mAs). High-pitch scanning possible for routine examination. 475 mm abdomen scannable within 5.5 seconds.
<b>High pitch scanning lung</b><br />0.5 sec/rotation, BP 1.08, 0.625mm slice width, 360mA (180mAs).High-pitch scanning is possible for routine examination400 mm chest can be scanned within 4.7 seconds.
High pitch scanning lung
0.5 sec/rotation, BP 1.08, 0.625mm slice width, 360mA (180mAs).High-pitch scanning is possible for routine examination400 mm chest can be scanned within 4.7 seconds.
<b>Colored mamma tumor lateral</b><br />3D volume rendering reconstruction for separation of different soft tissues.
Colored mamma tumor lateral
3D volume rendering reconstruction for separation of different soft tissues.
<b>Mamma tumor volume</b><br />Tumor volume calculation in soft tissue.
Mamma tumor volume
Tumor volume calculation in soft tissue.
<b>High quality MPR with normal scanning</b><br />2.0 sec/rot, normal scanning, 0.625mm x 32i, 150mA.<br />High image quality using normal scanning 64i mode for head MPR images.
High quality MPR with normal scanning
2.0 sec/rot, normal scanning, 0.625mm x 32i, 150mA.
High image quality using normal scanning 64i mode for head MPR images.